Over braiding flexible metallic conduit,Liquid Resistant,EMI shielding
|
water proof over Braided Flexible steel Conduit protecting machine cable from hot metal swarfs
water proof Electric Braided Flexible metallic Conduit for petrochemical industry wirings
Over braiding flexible metallic conduit,Liquid Resistant,EMI shielding
Clean data transmission in a noisy environment is an ever increasing requirement on todays crowded factory floors. Braided flexible steel conduit systems provide excellent EMI and RFI shielding, as well as mechanical protection, resulting in improved data transmission for factory automations.
OverBRAIDing Flexible metal conduit,water proof,Emc screening
*Resists high temperature and hot metal splashes
Constructions & features:
1)The core made of galvanized steel strips, hellically wound
with PVC covering. Providing good mechanical protection and
water tightness.
2) Metal wire over braiding provides increased pressure rating
(explosion proof),abrasion resistant and EMI shielding.
Suitable for:
1)Industrial enviroments, expecially suitable for
protections of machineries cables and wiring in wet and
hazardous locations.
2)Tele-communications equipments. EMI shielding of calbes.
3)Computer room wirings.
4)Public electrical facilities and installations.
1) Electromagnetic Interference (EMI) considerations:
*computers rooms *telecommunications * control systems
2) Abrasion resistance considerations:
*railway rolling stock *heavy duty industrial applications
3) Hot metal splashes resistance considerations:
*steel mills *petrochemical plants,Chemicals,Heavy Industrial wirings
4) Mechanical integrity:
*security/CCTV *anti-vandal applications
=======================
http://www.delikon.com
=======================
|
| |
 |
small bore flexible Stainless Steel Conduit for sensor wirings,small stainless steel flexible tubing
|
small bore flexible Stainless Steel Conduit for sensor wirings,small stainless steel flexible tubing
Flexible stainless steel conduit for electric wirings protections
Strip wound small ID flexible metallic conduit,hose for electrical wirings armoring
braided Small BORE Flexible stainless steel conduit,for automobile & industry wiring harness
Optical Fiber and sensors wirings protects Flexible metal conduit
Small bore Flexible metal conduit,for protection of instrument wirings
Small id Flexible Stainless Steel Conduit ( AT )
Small bore instrumentation tubing flexible conduit flexible stainless steel conduit for electric wirings
*Stainless steel strip (square locked or interlocked), very flexible *Corrosion Resistant
*EMI Shielding *Most suitable for instrument wiring protections.
MADE FROM STAINLESS STEEL STRIPS:
*ALL Stainless steel construction for corrosion resistant.
*Durable and long life.
*Designed for tight-spot installation and where continuous flexing is required
Applications:
Suitable for use in Industrial environments. Protection for stainless tubes, sensor cords or electric cords. It is designed to protect sensitive electronic circuits in applications such as sensors, electronic instruments and industrial control wirings.
Flexible Stainless Steel Conduit: Type AT is an ultra-flexible, stainless steel conduit designed primarily for OEM applications. A typical application would be armouring in specialty sensing devices, or medical equipment, including fiber-optics.
SMALL BORE HOSE
Delikon manufactures unique tubing that is relied on in numerous industries. The tubing is produced by helical coiling of a cold-rolled metal strip onto a spindle, with the helical coils being linked with each other by means of a special type of strip profile. Basic materials for the strip are stainless steel or galvanized steel strip. However, other metals are also available.
Applications:
Instrumentation tubing is used by manufacturers of various industries, such as Process & Control Instrumentation, Measuring & Controlling Devices, Analytical Instruments, Medical Instruments and many others with specific applications including temperature measuring, wiring conduit or armor cable and protective casing.
Instrumentation tubing is made in two configurations, or constructions, commonly called SquareLok and InterLok, and is often abbreviated as SL and FI.
--------------------------------
http://www.delikon.com
http://users4.nofeehost.com/delikon
--------------------------------
|
| |
 |
Ceramic fiber cotton
|
Our ceramic fiber are mainly ceramic fiber board,ceramic fiber felt,ceramic fiber blanket,ceramic fiber cotton and so on.
|
| |
 |
Ceramic fiber felt
|
Properties:
1. High heat stability, high chemical stability
2. Resistance to heat shocks
3. Low thermal conductivity and high absorption for sound
Usages:
1. Lining material for heating equipment as kiln and boiler etc.
2. Sealing material for furnace budging part and other high temperature sealing
3. Heat block elements for civilian use electrical appliance.
|
| |
 |
Carbon respirator NDFM1000
|
BRIEF DESCRIPTION
ACF FACE MASK IS MADE BY ACTIVATED CARBON FIBER, WHICH CAN ABSORB AND FILTER EFFECTIVELY. IT IS THE BEST CHOICE FOR DOCTORS, NURSES, PATIENT AND ALSO GOOD FOR THE STAFF IN CHEMICAL SPRAY DYING INDUSTRY.
This type of ACF cupped face mask has five layers one of which is activated carbon felt that can filter particles efficiently.
Properties:
1. Unique design
Comfort, Convenience, Sanitary and Healthy
2. Effective Adsorption of poison things or waste gas
It can filter efficiently some toxic gas such as organic gas, volatile things,
pesticide, SO2 or irritant gas, smell, bacterium and dust and so on.
3. Stop the dust smaller than 10 □m
Varieties:
1. 8 /9 -layer gauze ACF mask
2. Cupped ACF mask
3. ACF Disposable mask
4. ACF Moulded mask
5. FFP1,FFP2, N95, N99
We can produce as your order!
|
| |
 |
Carbon respirator NDHS4000
|
BRIEF DESCRIPTION
ACF FACE MASK IS MADE BY ACTIVATED CARBON FIBER, WHICH CAN ABSORB AND FILTER EFFECTIVELY. IT IS THE BEST CHOICE FOR DOCTORS, NURSES, PATIENT AND ALSO GOOD FOR THE STAFF IN CHEMICAL SPRAY DYING INDUSTRY
Structure:
Four layers: inner layer and outer layer are made of soft Polypropylene (P. P) which reduces the fiber falling and increases comfort for wearing. The filter layer is made of high-efficient melt blown cloth which resists dust and oil-free particle. And also one of layer is activated carbon fiber felt.
Properties:
1. High efficiency and low breathing resistance
2. The bridge of the nose part can be adjustable.
3. Built-in foam pads at the nose part are suitable for all kinds of face with
comfort. Suitable to long time wearing comfort. Cool latex-free cloth head
straps for comfortable wearing.
4. A perfect protection against toxic particles, an efficient adsorption and
removal of organic gases and odor.
Usages:
Suitable to chemical agriculture, solution cleaning, spray, printing, electronic, food processing, auto body shop, ship building. Ink and dyeing. Sterilizing, workshops, etc.
Varieties:
1. 8 /9 -layer gauze ACF mask
2. Cupped ACF mask
3. Disposable mask
4. 3-layer/2-layer non-woven cloth face mask
5. FFP1,FFP2, N95, N99
Note:
Can be used for about 8 hours to protect the wearers from particles and dust well and also can micro-filter some acidic particles at the same time but can not be used in protecting the gas. If you want this role, please choose our half face gas mask or gas mask.
|
| |
 |
Carbon respirator NDDS4000
|
BRIEF DESCRIPTION
ACF FACE MASK IS MADE BY ACTIVATED CARBON FIBER, WHICH CAN ABSORB AND FILTER EFFECTIVELY. IT IS THE BEST CHOICE FOR DOCTORS, NURSES, PATIENT AND ALSO GOOD FOR THE STAFF IN CHEMICAL SPRAY DYING INDUSTRY
Structure:
Four layers: inner layer and outer layer are made of soft Polypropylene (P. P) which reduces the fiber falling and increases comfort for wearing. The filter layer is made of high-efficient melt blown cloth which resists dust and oil-free particle. And also one of layer is activated carbon fiber felt.
Properties:
1. High efficiency and low breathing resistance
2. The bridge of the nose part can be adjustable.
3. Built-in foam pads at the nose part are suitable for all kinds of face with
comfort. Suitable to long time wearing comfort. Cool latex-free cloth head
straps for comfortable wearing.
4. A perfect protection against toxic particles, an efficient adsorption and
removal of organic gases and odor.
Usages:
Suitable to chemical agriculture, solution cleaning, spray, printing, electronic, food processing, auto body shop, ship building. Ink and dyeing. Sterilizing, workshops, etc.
Varieties:
1. 8 /9 -layer gauze ACF mask
2. Cupped ACF mask
3. Disposable mask
4. 3-layer/2-layer non-woven cloth face mask
5. FFP1,FFP2, N95, N99
Note:
Can be used for about 8 hours to protect the wearers from particles and dust well and also can micro-filter some acidic particles at the same time but can not be used in protecting the gas. If you want this role, please choose our half face gas mask or gas mask.
|
| |
 |
Carbon respirator NDDS4000
|
BRIEF DESCRIPTION
ACF FACE MASK IS MADE BY ACTIVATED CARBON FIBER, WHICH CAN ABSORB AND FILTER EFFECTIVELY. IT IS THE BEST CHOICE FOR DOCTORS, NURSES, PATIENT AND ALSO GOOD FOR THE STAFF IN CHEMICAL SPRAY DYING INDUSTRY
Structure:
Four layers: inner layer and outer layer are made of soft Polypropylene (P. P) which reduces the fiber falling and increases comfort for wearing. The filter layer is made of high-efficient melt blown cloth which resists dust and oil-free particle. And also one of layer is activated carbon fiber felt.
Properties:
1. High efficiency and low breathing resistance
2. The bridge of the nose part can be adjustable.
3. Built-in foam pads at the nose part are suitable for all kinds of face with
comfort. Suitable to long time wearing comfort. Cool latex-free cloth head
straps for comfortable wearing.
4. A perfect protection against toxic particles, an efficient adsorption and
removal of organic gases and odor.
Usages:
Suitable to chemical agriculture, solution cleaning, spray, printing, electronic, food processing, auto body shop, ship building. Ink and dyeing. Sterilizing, workshops, etc.
Varieties:
1. 8 /9 -layer gauze ACF mask
2. Cupped ACF mask
3. Disposable mask
4. 3-layer/2-layer non-woven cloth face mask
5. FFP1,FFP2, N95, N99
Note:
Can be used for about 8 hours to protect the wearers from particles and dust well and also can micro-filter some acidic particles at the same time but can not be used in protecting the gas. If you want this role, please choose our half face gas mask or gas mask.
|
| |
 |
Not-valved respirator NDFS3000
|
Properties:
1. High efficiency and low breathing resistance
2. The bridge of the nose part can be adjustable.
3. Built-in foam pads at the nose part are suitable for all kinds of face with
comfort. Suitable to long time wearing comfort. Cool latex-free cloth head
straps for comfortable wearing.
4. A perfect protection against toxic particles, an efficient adsorption and
removal of organic gases and odor.
Usages:
Suitable to textile, mining, construction, electronic, food processing, cement, disintegration, agriculture, farm garden, glass, cleaning, workshops,ect.
Structure:
Three layers: inner layer and outer layer are made of soft Polypropylene (P. P) which reduces the fiber falling and increases comfort for wearing. The filter layer is made of high-efficient melt blown cloth which resists dust and oil-free particle.
Note:
Can be used for about 8 hours to protect the wearers from particles and dust well but can not be used in protecting the gas. If you want this role, please choose our half face gas mask or gas mask.
|
| |
 |
Not-valved respirator NDKS3000
|
Properties:
1. High efficiency and low breathing resistance
2. The bridge of the nose part can be adjustable.
3. Built-in foam pads at the nose part are suitable for all kinds of face with
comfort. Suitable to long time wearing comfort. Cool latex-free cloth head
straps for comfortable wearing.
4. A perfect protection against toxic particles, an efficient adsorption and
removal of organic gases and odor.
Usages:
Suitable to textile, mining, construction, electronic, food processing, cement, disintegration, agriculture, farm garden, glass, cleaning, workshops,ect.
Structure:
Three layers: inner layer and outer layer are made of soft Polypropylene (P. P) which reduces the fiber falling and increases comfort for wearing. The filter layer is made of high-efficient melt blown cloth which resists dust and oil-free particle.
Note:
Can be used for about 8 hours to protect the wearers from particles and dust well but can not be used in protecting the gas. If you want this role, please choose our half face gas mask or gas mask.
|
| |
 |
Not-valved respirator NDPS3000
|
Properties:
1. High efficiency and low breathing resistance
2. The bridge of the nose part can be adjustable.
3. Built-in foam pads at the nose part are suitable for all kinds of face with
comfort. Suitable to long time wearing comfort. Cool latex-free cloth head
straps for comfortable wearing.
4. A perfect protection against toxic particles, an efficient adsorption and
removal of organic gases and odor.
Usages:
Suitable to textile, mining, construction, electronic, food processing, cement, disintegration, agriculture, farm garden, glass, cleaning, workshops,ect.
Structure:
Three layers: inner layer and outer layer are made of soft Polypropylene (P. P) which reduces the fiber falling and increases comfort for wearing. The filter layer is made of high-efficient melt blown cloth which resists dust and oil-free particle.
Note:
Can be used for about 8 hours to protect the wearers from particles and dust well but can not be used in protecting the gas. If you want this role, please choose our half face gas mask or gas mask.
|
| |
 |
slewing bearing,slewing ring,slewing ring bearing
|
TongLi has a manufacturing capacity of making 100000 pieces of slewing rings per year,up to 4000mm in diameter for different structures.The products cover 2000 different sizes and internal structures.With batches of products exported to Europe,America and Asia,TongLi Slewing Ring is a well known national brand foot-printing all over the world.
TongLi slewing rings are widely used by OEMs in all types of excavators,mobile cranes,tower cranes,rail cranes,water treatment equipments,and machine tools etc..The replacement slewing rings for different models of excavators,wind mills,solar system and mobile cranes provide the end users and distributors with more options.
|
| |
 |
Not-valved respirator NDGS1100
|
Properties:
1. High efficiency and low breathing resistance
2. The bridge of the nose part can be adjustable.
3. Built-in foam pads at the nose part are suitable for all kinds of face with
comfort. Suitable to long time wearing comfort. Cool latex-free cloth head
straps for comfortable wearing.
4. A perfect protection against toxic particles, an efficient adsorption and
removal of organic gases and odor.
Usages:
Suitable to textile, mining, construction, electronic, food processing, cement, disintegration, agriculture, farm garden, glass, cleaning, workshops,ect.
Structure:
Three layers: inner layer and outer layer are made of soft Polypropylene (P. P) which reduces the fiber falling and increases comfort for wearing. The filter layer is made of high-efficient melt blown cloth which resists dust and oil-free particle.
Note:
Can be used for about 8 hours to protect the wearers from particles and dust well but can not be used in protecting the gas. If you want this role, please choose our half face gas mask or gas mask.
|
| |
 |
Activated carbon fiber paper
|
BRIEF DESCRIPTION
ACTIVATED CARBON FIBER IS A NEW KIND OF FABRIC ABSORPTIVE MATERIAL WITH LARGE SPECIFIC SURFACE AREA AND PORE DIAMETER. AND IT HAS GREAT CAPACITY AND HIGH SPEED IN PERFORMING ADSORPTION AND DESORPTION. OUR PRODUCTS ARE MAINLY SORTED TO ACF CLOTH, ACF FELT, ACF PAPER.
Properties:
1. Huge adsorption with fast speed and excellent ability
2. Acid- resistance and alkali-resistance
3. Excellent electrical conductivity and chemical stability
4. Perfect heat resistance
5. Excellent regeneration
|
| |
 |
Half face gas mask NDSR3003
|
The type has four main parts: half-face mask body, filter, exhalation and inhalation valve and straps. It can only protect from dust equipped with filter cotton like NDSR3001.
1. Features
1. Efficient Adsorption and Filtration:
The canister is filled with activated carbon of high quality that can filter
efficiently different gas(please read the form of filter type carefully as follows.)
2. Comfortable Wear
Silicon rubber is adopted to our respirator, which makes the wearer
comfortable.
3. Long time of toxic gas resistance
4. Perfect air permeability
5. Low breathing resistance
Filter Type
Protection Range
1l# FILTER
HCN,Cyanogen,Arsine,Phosgene Chloropicrin ,Benzene, Bromomethane,Lewy gas, Phosphine.(escape only)
1# FILTER
HCN,Cyanogen,Arsine,Phosgene Chloropicrin ,Benzene, Bromomethane,Lewy gas, Phosphine,toxic smog(escape only).
2l# FILTER
CO,Organic vapor,Hydrocyanic acid and its derivatives,Toxic smoke,Poison and so on.
3l# FILTER
Benzene,Chlorine, Acetone ,Alcohol, Aniline, SO, CTC,Chloroform,Bromomethane ,Chloromethane Nitroalkane,Toxic smoke,Poison and so on.
3# FILTER
Benzene,Chlorine, Acetone ,Alcohol, Aniline, SO, CTC,Chloroform,Bromomethane ,Chloromethane Nitroalkane.
4l# FILTER
Ammonia,Hydrogen sulfide, Toxic smoke,Poison.
4# FILTER
Ammonia,Hydrogen sulfide.
5# FILTER
CO(escape only).
6# FILTER
Mercury Vapor
7l# FILTER
SO,Chlorine,Hydrogen sulfide ,Phosgene, Phosphorus and oxygen-containing organic pesticide.
7# FILTER
SO,Chlorine,Hydrogen sulfide ,Phosgene, Phosphorus and oxygen-containing organic pesticide.
8l# FILTER
Hydrogen sulfide,toxic smog
8# FILTER
Hydrogen sulfide
9l# FILTER
Formaldehyde ,Smoke
9# FILTER
Formaldehyde
10# FILTER
Efficiently filte dust and various types of odor
11# FILTER
Efficiently filte dust and various types of odor, Welding smoke, glass fiber.
2. Use And Maintenance∶
1. Shall be used personally
2. Shall choose different filters to be equipped with mask body according to your
protection scope.
3. Shall not used in the area with Oxygen concentration lower than 18%(calculated
by volume) or airtight places or the gas concentration higher than 0.1%
4. Please get out the gas area immediately if you smell slight gas when the filter
loses its role after some time of using. It can be used again after the filter is
replaced.
5. Shall be stored in clean, cool and dry place without exposure to sun or hot.
6. After using mask, perspiration, dirt or other left on all the parts should be wiped,
especially on the lens, expiratory trap, aspiratory trap. If necessary, mask body
can be cleaned by water and filter shall be wiped but avoid water in. If used in
the infected virus environment, mask body and filter can be wiped by using 1%
peracetic acid disinfectants. If necessary, mask body can be soaked in1%
peracetic acid disinfectants, but not filters. After disinfection, mask body can be
cleaned by water.
|
| |
 |
Full gas mask NDXM1123
|
The type has three parts: Mask body of NDXM1120 equipped with Water dispensers and a canister
1. APPLICATION AND FEATURE
when the ambient air is contaminated with chemical biological and radiated agents, the mask can provide effective protection to the wearer’s respiratory organs, eyes and facial skin. The mask is designed for use by military, police and civil defense and can also be used in industry, agriculture, warehouse, scientific research etc.
The mask is equipped with a drinking system. If necessary the mask body may be connected to a canteen by means of accessories to enable the wearer to intake water or fluids in contaminated areas. The flexibility of the mask body is suitable. The elastic straps have elasticity and can be adjusted at random to ensure a comfortable, leak-free fit. Two-eye lenses are manufactured from optical plastic with its surface treated specially. The lenses provide a wide visual field and excellent optical properties and have good abrasion and shook resistance.
The canister is filled with impregnated carbon of good quality and high efficiency filter paper and high efficiency filter paper and can filter out toxic gases and particulate aerosol from the influent air except carbon monoxide. The canister has a low resistance, lightweight and long life.
2.Specification:
Cyanogens chloride: not less than 50 minutes at 30 L/min.
1. 5mg/L, 80-80% RH conditions.
Hydrocyanic acid: not less than 50 minutes at 30L/min,3mg/L conditions.
2. Oil mist penetration coefficient: not more than 0.005% at 30L/min
3. Inhalation resistance: not more than 186 pa at 30L/min.
4. Exhalation resistance: not more than 100 pa at 30L/min.
5. Visual field: total not less than 75%, binocular visual field not less than 30%.
6. Storage life: more than 5 years.
3. USE AND MAINTENANCE
1. The mask body is divided into three sizes (small, medium and large on the left lower part of the mask body with a number:1(small),2(medium) or 3(large).The user shall choose a suitable mask according to the user’s head shape. If the user’s eyes after the mask has been worn are at the level of about10 mm above the horizontal center line lf lenses, it is shown that the selected size of the mask is suitable. If the eyes are above the value of 10mm, the mask is too small. If the eyes are below the value, the mask is too large.
2. Use of drinking device. A special canteen cap should be screwed previously to the canteen .when the wearer needs to drink water, unscrew the protective covers from the canteen cap and the water inlet valve, screw the ends of the connecting tube to the canteen cap and the water inlet valve, actuate the water inlet valve by hand to keep a suction tube in the mouth.
3. After using mask, perspiration, dirt or other left on all the parts should be wiped, especially on the lens, expiratory trap, aspiratory trap. If necessary, mask body can be cleaned by water and filter shall be wiped but avoid water in.If used in the infected virus environment, mask body and filter can be wiped by using 1% peracetic acid disinfectants. If necessary, mask body can be soaked in1% peracetic acid disinfectants, but not filters. After disinfection , mask body can be cleaned by water.
4. Adsorption capacity of the canister can be decreased for toxic gases after the canister has absorbed the moisture. The closure cap and the plug should usually be attached to the canister to prevent the ingress of moisture.
5. The gas masks should be stored in a cool dry place. If the masks are not in use for a longer time, a support should be placed inside the mask body to prevent the deformation. The mask body must not be placed or contacted with organic solvent.
|
| |
 |
Full gas mask NDXM1120-0
|
BRIEF DESCRIPTION
GB2890-1995,GB/T2626-1992,ISO
The type has two parts: Mask body of two triangular lens equipped with one canister(MQ1L) used in the chemical industry.Canister just can be all types.
1. APPLICATION AND FEATURE
when the ambient air is contaminated with chemical biological and radiated agents, the mask can provide effective protection to the wearer’s respiratory organs, eyes and facial skin. The mask is designed for use by military, police and civil defense and can also be used in industry, agriculture, warehouse, scientific research etc.
The flexibility of the mask body is suitable. The elastic straps have elasticity and can be adjusted at random to ensure a comfortable, leak-free fit. Two-eye lenses are manufactured from optical plastic with its surface treated specially. The lenses provide a wide visual field and excellent optical properties and have good abrasion and shook resistance.
The canister is filled with impregnated carbon of good quality and high efficiency filter paper and high efficiency filter paper and can filter out toxic gases and particulate aerosol from the influent air except carbon monoxide. The canister has a low resistance, lightweight and long life.
2.SPECIFICATION:
Cyanogens chloride: not less than 50 minutes at 30 L/min.
1. 5mg/L, 80-80% RH conditions.
Hydrocyanic acid: not less than 50 minutes at 30L/min,3mg/L conditions.
2. Oil mist penetration coefficient: not more than 0.005% at 30L/min
3. Inhalation resistance: not more than 186 pa at 30L/min.
4. Exhalation resistance: not more than 100 pa at 30L/min.
5. Visual field: total ≮ 75°, binocular visual field ≮30°.
6. Storage life: more than 5 years.
3. USE AND MAINTENANCE
1. The mask body is divided into three sizes (small, medium and large on the left lower part of the mask body with a number:1(small),2(medium) or 3(large).The user shall choose a suitable mask according to the user’s head shape. If the user’s eyes after the mask has been worn are at the level of about10 mm above the horizontal center line lf lenses, it is shown that the selected size of the mask is suitable. If the eyes are above the value of 10mm, the mask is too small. If the eyes are below the value, the mask is too large.
2. After using mask, perspiration, dirt or other left on all the parts should be wiped, especially on the lens, expiratory trap, aspiratory trap. If necessary, mask body can be cleaned by water and filter shall be wiped but avoid water in.If used in the infected virus environment, mask body and filter can be wiped by using 1% peracetic acid disinfectants. If necessary, mask body can be soaked in1% peracetic acid disinfectants, but not filters. After disinfection , mask body can be cleaned by water.
3. Adsorption capacity of the canister can be decreased for toxic gases after the canister has absorbed the moisture. The closure cap and the plug should usually be attached to the canister to prevent the ingress of moisture.
4. The gas masks should be stored in a cool dry place. If the masks are not in use for a longer time, a support should be placed inside the mask body to prevent the deformation. The mask body must not be placed or contacted with organic solvent.
|
| |
 |
Full gas mask NDSM2002
|
BRIEF DESCRIPTION
The type has two parts: Mask body equipped with one canister which shall be MQ series.
1. APPLICATION AND FEATURE
---when the ambient air is contaminated with chemical biological and radiated agents, the mask can provide effective protection to the wearer’s respiratory organs, eyes and facial skin. The mask is designed for use by military, police and civil defense and can also be used in industry, agriculture, warehouse, scientific research etc.
---The flexibility of the mask body is suitable. The elastic straps have elasticity and can be adjusted at random to ensure a comfortable, leak-free fit. Large triangular lenses are manufactured from optical plastic with its surface treated specially. The lenses provide a wide visual field and excellent optical properties and have good abrasion and shook resistance.
---The canister is filled with impregnated carbon of good quality and high efficiency filter paper and high efficiency filter paper and can filter out toxic gases and particulate aerosol from the influent air except carbon monoxide. The canister has a low resistance, lightweight and long life.
2. SPECIFICATION:
Cyanogens chloride: not less than 50 minutes at 30 L/min.
1. 5mg/L, 80-80% RH conditions.
Hydrocyanic acid: not less than 50 minutes at 30L/min,3mg/L conditions.
2. Oil mist penetration coefficient: not more than 0.005% at 30L/min
3. Inhalation resistance: not more than 186 pa at 30L/min.
4. Exhalation resistance: not more than 100 pa at 30L/min.
5. Visual field: total ≮ 75°, binocular visual field ≮60°, Below visual field≮40°
6. Storage life: more than 5 years.
3. USE AND MAINTENANCE
1. The mask body is divided into three sizes (small, medium and large on the left lower part of the mask body with a number:1(small),2(medium) or 3(large).The user shall choose a suitable mask according to the user’s head shape. If the user’s eyes after the mask has been worn are at the level of about10 mm above the horizontal center line lf lenses, it is shown that the selected size of the mask is suitable. If the eyes are above the value of 10mm, the mask is too small. If the eyes are below the value, the mask is too large.
2. After using mask, perspiration, dirt or other left on all the parts should be wiped, especially on the lens, expiratory trap, aspiratory trap. If necessary, mask body can be cleaned by water and filter shall be wiped but avoid water in.If used in the infected virus environment, mask body and filter can be wiped by using 1% peracetic acid disinfectants. If necessary, mask body can be soaked in1% peracetic acid disinfectants, but not filters. After disinfection , mask body can be cleaned by water.
3. Adsorption capacity of the canister can be decreased for toxic gases after the canister has absorbed the moisture. The closure cap and the plug should usually be attached to the canister to prevent the ingress of moisture.
4. The gas masks should be stored in a cool dry place. If the masks are not in use for a longer time, a support should be placed inside the mask body to prevent the deformation. The mask body must not be placed or contacted with organic solvent.
|
| |
 |
Full gas mask NDXM1123
|
BRIEF DESCRIPTION
The type has three parts: Mask body with Water dispensers pipe and one canister
1. APPLICATION AND FEATURE
when the ambient air is contaminated with chemical biological and radiated agents, the mask can provide effective protection to the wearer’s respiratory organs, eyes and facial skin. The mask is designed for use by military, police and civil defense and can also be used in industry, agriculture, warehouse, scientific research etc.
The mask is equipped with a drinking system. If necessary the mask body may be connected to a canteen by means of accessories to enable the wearer to intake water or fluids in contaminated areas. The flexibility of the mask body is suitable. The elastic straps have elasticity and can be adjusted at random to ensure a comfortable, leak-free fit. Two-eye lenses are manufactured from optical plastic with its surface treated specially. The lenses provide a wide visual field and excellent optical properties and have good abrasion and shook resistance.
The canister is filled with impregnated carbon of good quality and high efficiency filter paper and high efficiency filter paper and can filter out toxic gases and particulate aerosol from the influent air except carbon monoxide. The canister has a low resistance, lightweight and long life.
2.Specification:
Cyanogens chloride: not less than 50 minutes at 30 L/min.
1. 5mg/L, 80-80% RH conditions.
Hydrocyanic acid: not less than 50 minutes at 30L/min,3mg/L conditions.
2. Oil mist penetration coefficient: not more than 0.005% at 30L/min
3. Inhalation resistance: not more than 186 pa at 30L/min.
4. Exhalation resistance: not more than 100 pa at 30L/min.
5. Visual field: total not less than 75%, binocular visual field not less than 30%.
6. Storage life: more than 5 years.
3. USE AND MAINTENANCE
1. The mask body is divided into three sizes (small, medium and large on the left lower part of the mask body with a number:1(small),2(medium) or 3(large).The user shall choose a suitable mask according to the user’s head shape. If the user’s eyes after the mask has been worn are at the level of about10 mm above the horizontal center line lf lenses, it is shown that the selected size of the mask is suitable. If the eyes are above the value of 10mm, the mask is too small. If the eyes are below the value, the mask is too large.
2. Use of drinking device. A special canteen cap should be screwed previously to the canteen .when the wearer needs to drink water, unscrew the protective covers from the canteen cap and the water inlet valve, screw the ends of the connecting tube to the canteen cap and the water inlet valve, actuate the water inlet valve by hand to keep a suction tube in the mouth.
3. After using mask, perspiration, dirt or other left on all the parts should be wiped, especially on the lens, expiratory trap, aspiratory trap. If necessary, mask body can be cleaned by water and filter shall be wiped but avoid water in.If used in the infected virus environment, mask body and filter can be wiped by using 1% peracetic acid disinfectants. If necessary, mask body can be soaked in1% peracetic acid disinfectants, but not filters. After disinfection , mask body can be cleaned by water.
4. Adsorption capacity of the canister can be decreased for toxic gases after the canister has absorbed the moisture. The closure cap and the plug should usually be attached to the canister to prevent the ingress of moisture.
5. The gas masks should be stored in a cool dry place. If the masks are not in use for a longer time, a support should be placed inside the mask body to prevent the deformation. The mask body must not be placed or contacted with organic solvent.
|
| |
 |
Full gas mask NDXM1121-1
|
BRIEF DESCRIPTION
1. Mask with Gas-guide tube and a Canister with build-in transmitter for the convenience of talking when working.
2. Size of Canister: big, medium, small
3. Length of Gas-guide tube: 0.5m, 1m, 5m, 10m, 15m, 20m
4. Material of mask body:natural rubber
5. Can be equipped with different filters according to the environment.
|
| |
 |
Full gas mask NDXM1121-2
|
BRIEF DESCRIPTION
1. Mask with Gas-guide tube and a Canister with build-in transmitter for the convenience of talking when working.
2. Size of Canister: big, medium, small
3. Length of Gas-guide tube: 0.5m, 1m, 5m, 10m, 15m, 20m
4. Material of mask body:natural rubber
5. Can be equipped with different filters according to the environment.
|
| |
 |
Full gas mask NDXM1120-1-T
|
BRIEF DESCRIPTION
GB2890-1995,GB/T2626-1992,ISO
The type has two parts: Mask body of two triangular lens equipped with one canister which shall be MQ series.
1. APPLICATION AND FEATURE
when the ambient air is contaminated with chemical biological and radiated agents, the mask can provide effective protection to the wearer’s respiratory organs, eyes and facial skin. The mask is designed for use by military, police and civil defense and can also be used in industry, agriculture, warehouse, scientific research etc.
The flexibility of the mask body is suitable. The elastic straps have elasticity and can be adjusted at random to ensure a comfortable, leak-free fit. Two-eye lenses are manufactured from optical plastic with its surface treated specially. The lenses provide a wide visual field and excellent optical properties and have good abrasion and shook resistance.
The canister is filled with impregnated carbon of good quality and high efficiency filter paper and high efficiency filter paper and can filter out toxic gases and particulate aerosol from the influent air except carbon monoxide. The canister has a low resistance, lightweight and long life.
2.SPECIFICATION:
Cyanogens chloride: not less than 50 minutes at 30 L/min.
1. 5mg/L, 80-80% RH conditions.
Hydrocyanic acid: not less than 50 minutes at 30L/min,3mg/L conditions.
2. Oil mist penetration coefficient: not more than 0.005% at 30L/min
3. Inhalation resistance: not more than 186 pa at 30L/min.
4. Exhalation resistance: not more than 100 pa at 30L/min.
5. Visual field: total ≮ 75°, binocular visual field ≮30°.
6. Storage life: more than 5 years.
3. USE AND MAINTENANCE
1. The mask body is divided into three sizes (small, medium and large on the left lower part of the mask body with a number:1(small),2(medium) or 3(large).The user shall choose a suitable mask according to the user’s head shape. If the user’s eyes after the mask has been worn are at the level of about10 mm above the horizontal center line lf lenses, it is shown that the selected size of the mask is suitable. If the eyes are above the value of 10mm, the mask is too small. If the eyes are below the value, the mask is too large.
2. After using mask, perspiration, dirt or other left on all the parts should be wiped, especially on the lens, expiratory trap, aspiratory trap. If necessary, mask body can be cleaned by water and filter shall be wiped but avoid water in.If used in the infected virus environment, mask body and filter can be wiped by using 1% peracetic acid disinfectants. If necessary, mask body can be soaked in1% peracetic acid disinfectants. but not filters. After disinfection , mask body can be cleaned by water.
3. Adsorption capacity of the canister can be decreased for toxic gases after the canister has absorbed the moisture. The closure cap and the plug should usually be attached to the canister to prevent the ingress of moisture.
4. The gas masks should be stored in a cool dry place. If the masks are not in use for a longer time, a support should be placed inside the mask body to prevent the deformation. The mask body must not be placed or contacted with organic solvent.
|
| |
 |
Full gas mask NDXM1122
|
BRIEF DESCRIPTION
GAS MASK(ISO9001) IS DESIGNED TO PROVIDE PROTECTION AGAINST CHEMICAL, BIOLOGICAL AND RADIOACTIVE SUBSTANCE, WHICH CAN BE USED IN MILITARY, POLICE, CIVIL DEFENSE, INDUSTRY, AGRICULTURE AND RESEARCH WORK AND OTHERS.
The type has two parts: Full-face Mask body equipped with one canister used in the chemical industry.Length of gas-guide tube is about 5m,10m,15m,20m,0.5m,1m. Filter can be MP or MD series which shall be put into the bag aslant the body.
1. APPLICATION AND FEATURE
when the ambient air is contaminated with chemical biological and radiated agents, the mask can provide effective protection to the wearer’s respiratory organs, eyes and facial skin. The mask is designed for use by military, police and civil defense and can also be used in industry, agriculture, warehouse, scientific research etc.
The flexibility of the mask body is suitable. The elastic straps have elasticity and can be adjusted at random to ensure a comfortable, leak-free fit. Large triangular lenses are manufactured from optical plastic with its surface treated specially. The lenses provide a wide visual field and excellent optical properties and have good abrasion and shook resistance.
The canister is filled with impregnated carbon of good quality and high efficiency filter paper and high efficiency filter paper and can filter out toxic gases and particulate aerosol from the influent air except carbon monoxide. The canister has a low resistance, lightweight and long life.
2.SPECIFICATION:
Cyanogens chloride: not less than 50 minutes at 30 L/min.
1. 5mg/L, 80-80% RH conditions.
Hydrocyanic acid: not less than 50 minutes at 30L/min,3mg/L conditions.
2. Oil mist penetration coefficient: not more than 0.005% at 30L/min
3. Inhalation resistance: not more than 186 pa at 30L/min.
4. Exhalation resistance: not more than 100 pa at 30L/min.
5. Visual field: total ≮ 75°, binocular visual field ≮60°, Below visual field≮40°6. Storage life: more than 5 years.
3. USE AND MAINTENANCE
1. The mask body is divided into three sizes (small, medium and large on the left lower part of the mask body with a number:1(small),2(medium) or 3(large).The user shall choose a suitable mask according to the user’s head shape. If the user’s eyes after the mask has been worn are at the level of about10 mm above the horizontal center line lf lenses, it is shown that the selected size of the mask is suitable. If the eyes are above the value of 10mm, the mask is too small. If the eyes are below the value, the mask is too large.
2. After using mask, perspiration, dirt or other left on all the parts should be wiped, especially on the lens, expiratory trap, aspiratory trap. If necessary, mask body can be cleaned by water and filter shall be wiped but avoid water in.If used in the infected virus environment, mask body and filter can be wiped by using 1% peracetic acid disinfectants. If necessary, mask body can be soaked in1% peracetic acid disinfectants, but not filters. After disinfection , mask body can be cleaned by water.
3. Adsorption capacity of the canister can be decreased for toxic gases after the canister has absorbed the moisture. The closure cap and the plug should usually be attached to the canister to prevent the ingress of moisture.
4. The gas masks should be stored in a cool dry place. If the masks are not in use for a longer time, a support should be placed inside the mask body to prevent the deformation. The mask body must not be placed or contacted with organic solvent.
|
| |
 |
Ceramic fiber blanket
|
Our ceramic fiber is mainly sorted to felt, board, blanket, cotton.
Properties:
1. High heat stability and high chemical stability
2. Resistance to heat shock
3. Low thermal conductivity and high absorption of sound
Usages:
1. Lining material for heating equipment as kiln and boiler etc
2. Sealing material for furnace budging part and other high temperature sealing
3. Heat block elements for civilian use electrical appliance
|
| |
 |
Ceramic fiber board
|
Our ceramic fiber is mainly sorted to felt, board, blanket, cotton.
Properties:
1. High heat stability and high chemical stability
2. Resistance to heat shock
3. Low thermal conductivity and high absorption of sound
Usages:
1. Lining material for heating equipment as kiln and boiler etc
2. Sealing material for furnace budging part and other high temperature sealing
3. Heat block elements for civilian use electrical appliance
|
| |
 |
Activated carbon non-woven cloth
|
Brief description:
Activated carbon non-woven cloth is made from non-woven cloth adhered to activated carbon powder by macromolecule adhesive material. It can adsorb all kinds of toxic gas, such as benzene, formaldehyde, sulfur dioxide, ammonia, fine dust, and sprays and so on. It is chiefly applied to chemical industry, pharmaceutical, agricultural chemicals and so on.
Specification:
Width: 900-1100mm Length: 200-1000m
Thickness: 0.2-1.2mm Weight: 30-200g/m2
Benzene adsorption: 20-30 wt%
Carbon contents : 30-50 %
|
| |
 |
Activated carbon fiber felt
|
Activated carbon fiber is a new kind of fabric absorptive material with large specific surface area and pore diameter. And it has great capacity and high speed in performing adsorption and desorption. Our products is mainly sorted to ACF cloth, ACF felt, ACF paper.
Properties:
1. Huge adsorption with fast speed and excellent ability
2. Acid- resistance and alkali-resistance
3. Excellent electrical conductivity and chemical stability
4. Perfect heat resistance
5. Excellent regeneration
Usage:
Activated carbon fiber can be used in solvent recovery from air stream such as the vapor of benzene, ketone, ester, petroleum and kinds of toxic gases. Also it can be used in air cleaning, wastewater treatment, drinking water purification. In addition, it can be used to make anti-corrosive materials and heat insulting material.
|
| |
 |
Activated carbon fiber cloth
|
Activated carbon fiber is a new kind of fabric absorptive material with large specific surface area and pore diameter. And it has great capacity and high speed in performing adsorption and desorption. Our products is mainly sorted to ACF cloth, ACF felt, ACF paper.
Properties:
1. Huge adsorption with fast speed and excellent ability
2. Acid- resistance and alkali-resistance
3. Excellent electrical conductivity and chemical stability
4. Perfect heat resistance
5. Excellent regeneration
Usage:
Activated carbon fiber can be used in solvent recovery from air stream such as the vapor of benzene,ketone,ester,petroleum and kinds of toxic gases. Also it can be used in air cleaning, wastewater treatment, drinking water purification. In addition, it can be used to make anti-corrosive materials and heat insulting material.
|
| |
 |
Activated carbon
|
Activated carbon is made from strictly selected coal by using special technology.It has large specifict area and large proe volume.
Usage:
1. Remove H2S and other sulfides
2. Recovery benzene, xylene, ether, ethanol, gasoline
3. Carrier or catalyst in the synthetic industry
4. Remove pollutants in air or used in Gas separation and purification
5. Used for industrial water, domestic water and sewage purification
6. Separation of nitrogen and carbon dioxide gas from the air, or separation of methane from the fermentation,decomposition from formaldehyde gas and separation of hydrogen and other from blast furnace gas
7. Production of impregnated carbon,and used in all kinds of gas mask as filtration in industry
8. Adsorption of gas or liquid hazardous substances, removal of various organic vapors or filter of harmful gases and unpleasant smell in the air, etc.
|
| |
 |
Half face gas mask NDSR3008
|
Features:
Two-filter protective mask can be easily worn comfortably for the wearer with a good air permeability, light weight and low breathing.
Usages:
It can be used to protect the wearer form organic gas, benzene, gasoline, acetone caused in some workplaces.
|
| |
 |
Over all anti-poison clothing
|
Over all Anti-poison Clothing ---made from cotton cloth blended with
Properties:
1. Efficient absorbability and Perfect evenness
2. Comfortable Wear
Discharge sweat efficiently due to perfect air permeability to avoid sultriness
3. Anti-chemicals
100% activated carbon fiber without any other materials like additive and adhesive
4. Wash resistance
More than ten times to wash without decreasing its efficiency
5. Easy regeneration
It can be reused after being regenerated by hot air or hot vapor.
USAGES∶
This Type is applied for the military or civil as skin-protective equipment to protect the wearer from virus or flame and so on. It shall be equipped with gas mask, boots and gloves as a set. Also it plays an effective role in protecting against a wide variety of chemical agents in all three states. Our protective suit includes overall one and separate one。
|
| |
 |
Half face gas mask NDSR3004
|
Features:
One-filter protective mask can be easily worn comfortably for the wearer with a good air permeability, light weight and low breathing.
Usages:
It can be used to protect the wearer form organic gas, benzene, gasoline, acetone caused in some workplaces.
|
| |
 |
Half face gas mask NDSR3002
|
The type has four main parts: half-face mask body, filter, exhalation and inhalation valve and straps.
Features:
1. Efficient Adsorption and Filtration:
The canister is filled with activated carbon of high quality that can filter
efficiently different gas(please read the form of filter type carefully as follows.)
2. Comfortable Wear
Silicon rubber is adopted to our respirator, which makes the wearer comfortable.
3. Long time of toxic gas resistance
4. Perfect air permeability
5. Low breathing resistance
|
| |
 |
Rubber respirator NDSR3001
|
This type respirator can exchange the filter to protect from toxic gases like NDSR3003.
Features:
1. Efficient Adsorption and Filtration:
The canister is filled with a piece of filter cotton that can filter fine dust
and sprays and so on.
2. Comfortable Wear
Silicon rubber is adopted to our respirator, which makes the wearer
comfortable.
3. Long time of dust resistance
4. Perfect air permeability
5. Low breathing resistance
Usages:
It can be applied to protect the wearer from a lot of dust produced in the workplaces like building, mining, ironing, and material processing.
|
| |
 |
Full gas mask NDXM1126-2002
|
The type has two parts: Mask body of NDSM2002-M equipped with one canister which can be used with helmet according the different size of mask and helmet.
1. APPLICATION AND FEATURE
when the ambient air is contaminated with chemical biological and radiated agents, the mask can provide effective protection to the wearer’s respiratory organs, eyes and facial skin. The mask is designed for use by military, police and civil defense and can also be used in industry, agriculture, warehouse, scientific research etc.
The flexibility of the mask body is suitable. The elastic straps have elasticity and can be adjusted at random to ensure a comfortable, leak-free fit. Large triangular lenses are manufactured from optical plastic with its surface treated specially. The lenses provide a wide visual field and excellent optical properties and have good abrasion and shook resistance.
The canister is filled with impregnated carbon of good quality and high efficiency filter paper and high efficiency filter paper and can filter out toxic gases and particulate aerosol from the influent air except carbon monoxide. The canister has a low resistance, lightweight and long life.
2.SPECIFICATION:
Cyanogens chloride: not less than 50 minutes at 30 L/min.
1. 5mg/L, 80-80% RH conditions.
Hydrocyanic acid: not less than 50 minutes at 30L/min,3mg/L conditions.
2. Oil mist penetration coefficient: not more than 0.005% at 30L/min
3. Inhalation resistance: not more than 186 pa at 30L/min.
4. Exhalation resistance: not more than 100 pa at 30L/min.
5. Visual field: total ≮ 75°, binocular visual field ≮60°. Below visual field≮40°
6. Storage life: more than 5 years.
3. USE AND MAINTENANCE
1. The mask body is divided into three sizes (small, medium and large on the left lower part of the mask body with a number:1(small),2(medium) or 3(large).The user shall choose a suitable mask according to the user’s head shape. If the user’s eyes after the mask has been worn are at the level of about10 mm above the horizontal center line lf lenses, it is shown that the selected size of the mask is suitable. If the eyes are above the value of 10mm, the mask is too small. If the eyes are below the value, the mask is too large.
2. After using mask, perspiration, dirt or other left on all the parts should be wiped, especially on the lens, expiratory trap, aspiratory trap. If necessary, mask body can be cleaned by water and filter shall be wiped but avoid water in.If used in the infected virus environment, mask body and filter can be wiped by using 1% peracetic acid disinfectants. If necessary, mask body can be soaked in1% peracetic acid disinfectants, but not filters. After disinfection , mask body can be cleaned by water.
3. Adsorption capacity of the canister can be decreased for toxic gases after the canister has absorbed the moisture. The closure cap and the plug should usually be attached to the canister to prevent the ingress of moisture.
4. The gas masks should be stored in a cool dry place. If the masks are not in use for a longer time, a support should be placed inside the mask body to prevent the deformation. The mask body must not be placed or contacted with organic solvent.
|
| |
 |
Rubber respirator NDSR3007
|
Features:
This type respirator is made by natural rubber which is comfortable for the wearer without stimulating the skin and can be used for a long time due to low breathing resistance and high efficiency of filter cotton.
Usages:
It can be applied to protect the wearer from a lot of dust produced in the workplaces like building, mining, ironing, and material processing. Dust is the enemy of human health. The dust is the biggest enemy of our human being. The finer the dust, the easier people can inhale. It can enter respiratory directly into the alveolar deposition, if exists long, it will accumulate pneumonia or other pneumoconiosis disease. Choose our products, choose the health.
|
| |
 |
Rubber respirator NDSR3006
|
Features:
This type respirator is made by natural rubber which is comfortable for the wearer without stimulating the skin and can be used for a long time due to low breathing resistance and high efficiency of filter cotton.
Usages:
It can be applied to protect the wearer from a lot of dust produced in the workplaces like building, mining, ironing, and material processing. Dust is the enemy of human health. The dust is the biggest enemy of our human being. The finer the dust, the easier people can inhale. It can enter respiratory directly into the alveolar deposition, if exists long, it will accumulate pneumonia or other pneumoconiosis disease. Choose our products, choose the health.
|
| |
 |
Porours anti-poison clothing
|
Porous Anti-poison Clothing ---made from cotton cloth blended with
Properties:
1. Efficient absorbability and Perfect evenness
2. Comfortable Wear
Discharge sweat efficiently due to perfect air permeability to avoid sultriness
3. Anti-chemicals
100% activated carbon fiber without any other materials like additive and adhesive
4. Wash resistance
More than ten times to wash without decreasing its efficiency
5. Easy regeneration
It can be reused after being regenerated by hot air or hot vapor.
USAGES∶
This Type is applied for the military or civil as skin-protective equipment to protect the wearer from virus or flame and so on. It shall be equipped with gas mask, boots and gloves as a set. Also it plays an effective role in protecting against a wide variety of chemical agents in all three states. Our protective suit includes overall one and separate one。
|
| |
 |
Full gas mask NDXM1125
|
This type is used for the wearers who escape from the fire.
1. Structure and properties∶
1. Hood piece is made from flame-retardant and heat-insulated material and can withstand at a high temperature of 800℃ in a short time
2. The panoramic lens has a perfect sight to ensure the wearer see clearly routes during escaping.
3. Face piece is made by rubber with a good form for the wearer’s face with comfort.
4. Leakage coefficient is low and breathing resistant is vey low.
5. Canister shall be sealed completely before using, which can filter toxic gas and smoke efficiently, such as Ammonia, hydrogen chloride, hydrogen cyanide, nitrogen oxides, hydrogen sulfide and SO2,and especially have a perfect and reliable protection against suspended particles of CO in the smog.
2. Main technical indicators∶
|
| |
 |
Full gas mask NDXM1121
|
1. Mask with Gas-guide tube and a Canister with build-in transmitter for the convenience of talking when working.
2. Size of Canister: big, medium, small
3. Length of Gas-guide tube: 0.5m, 1m, 5m, 10m, 15m, 20m
4. Material of mask body:natural rubber
5. Can be equipped with different filters according to the environment.
|
| |
|